CDE Detailed Report
Disease: Sickle Cell Disease
Sub-Domain: Additional Proposed Instruments
CRF: PhenX CDEs

Displaying 101 - 150 of 378
CDE ID CDE Name Variable Name Definition Short Description Additional Notes (Question Text) Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guideline) Sub Domain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type Source Form Set Form Field Domain CDASH Variable CDASH Definition CDASH Label Controlled Terminology Prompt Essentiality Question Text CDASH imp guidance SDTM IG target csDSR PhenX Data Type CRF Completion Inst SDTMIG Target Var SDTMIG Target Map Codelist Name PVs Pre Pop Value Query Display List Style
C56413 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Similarities T score WASIIISimTScore The T score converted from the raw score that the subject received on the Similarities subtest of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) . The T score converted from the raw score that the subject received on the Similarities subtest of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 11:23:35.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

20 80
C12468 Imaging magnetic resonance imaging performed multiple count ImgMRIPerfMultiCt The count representing of the number of magnetic resonance imaging (MRI) sessions performed on the participant/subject The count representing of the number of magnetic resonance imaging (MRI) sessions performed on the participant/subject 2;3;4;5;6;>6;2;3;4;5;6;>6 2;3;4;5;6;>6;2;3;4;5;6;>6 Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14034 Vasomotor response (VMR) vessel anatomic site VMRVesselAntmicSite Indicates vasomotor response (VMR) vessel type Indicates vasomotor response (VMR) vessel type M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar;MCA;Other, specify M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar;Middle cerebral artery;Other, specify Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C13922 Imaging common carotid artery (CCA) externalization indicator ImgCCAExternalizInd Indicates common carotid artery (CCA) externalization Indicates common carotid artery (CCA) externalization Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C54605 Informant participant relationship duration unit of measure InfrmntPrtcpntRltnshpDurUOM Field related to 'Informant participant relationship duration' specifying the unit of measure of the duration for which the informant has known the participant Field related to 'Informant participant relationship duration' specifying the unit of measure of the duration for which the informant has known the participant Weeks;Months;Years Weeks;Months;Years Alphanumeric Adult;Pediatric Supplemental 1.00 2017-03-22 09:46:35.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C12504 Imaging gray matter hyperintensity T2 fluid attenuated inversion recovery site ImgGryMtrHyperT2FLAIRSiteTyp The type of anatomical site of the grey matter hyperintensity on T2/FLAIR (fluid attenuated inversion recovery) images The type of anatomical site of the grey matter hyperintensity on T2/FLAIR images Putamen;Caudate;Other, specify;Cerebellar nuclei;Colliculi;Floor of the fourth ventricle;Pallidum;Periaqueductal grey;Red nucleus;Substantia nigra;Mammillary body;Subthalmic nucleus;Thalamus Putamen;Caudate;Other, specify;Cerebellar nuclei;Colliculi;Floor of the fourth ventricle;Pallidum;Periaqueductal grey;Red nucleus;Substantia nigra;Mammillary body;Subthalmic nucleus;Thalamus Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C13240 National Institutes of Health Stroke Scale (NIHSS) - Limb ataxia score NIHSSLimbAtaxiaScore Limb ataxia assessed using the NIH Stroke Scale (NIHSS) Limb ataxia assessed using the NIH Stroke Scale (NIHSS) 0;1;2;UN;0;1;2;UN Absent;Present in one limb;Present in two limbs;Amputation or joint fusion, explain;Absent;Present in one limb;Present in two limbs;Amputation or joint fusion, explain Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C18855 Imaging other cortical abnormality other text ImgOthrCorticalAbnrmlyOTH The free-text field related to 'Imaging other cortical abnormality type' specifying other text. The type of other cortical abnormality The free-text field related to 'Imaging other cortical abnormality type' specifying other text. The type of other cortical abnormality Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C56380 Conners Continuous Performance Test 3rd Edition (CPT3) - Inattentiveness omission count ConnersCPT3InaOmmCt The number of missed targets, as part of the Conners Continuous Performance Test 3rd Edition (CPT3) The number of missed targets, as part of the Conners Continuous Performance Test 3rd Edition (CPT3) Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-09 15:29:58.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0
C08238 Imaging repetition gap value ImgRepetitionGapVal Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

millisecond
C14012 Intracranial stenosis peak systolic velocity (PSV) criterion result IntracranStenoPSVCriterReslt Indicates intracranial stenosis peak systolic velocity (PSV) criterion Indicates intracranial stenosis peak systolic velocity (PSV) criterion Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X 255

Free-Form Entry

C13901 Imaging patient type ImgPatientTyp Indicates imaging patient type Indicates imaging patient type Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C21493 Wechsler Adult Intelligence Scale IV (WAIS IV) - Digit span backward subtest item number WAISIVDSBItemNum Item number, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Backward subtest Item number, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Backward subtest 1;2;3;4;5;6;7;8 Item 1;Item 2;Item 3;Item 4;Item 5;Item 6;Item 7;Item 8 Numeric Values Adult;Pediatric Supplemental 1.00 2015-07-22 11:32:44.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C56425 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Verbal Comprehension percentile rank value WASIIIVerbCompPrcntRankVal The percentile rank the subject placed into with respect to the Verbal Comprehension subtests, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). The percentile rank the subject placed into with respect to the Verbal Comprehension subtests, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 12:05:57.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 100 percent
C12483 Imaging cortex-polymicrogyria indicator ImgCortexPolymicrogyriaInd Indicator of whether a developmental malformation of the human brain characterized by an excessive number of small convolutions (gyri) on the surface of the brain is present Indicator of whether a developmental malformation of the human brain characterized by an excessive number of small convolutions (gyri) on the surface of the brain is present Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14681 Pediatric Migraine Disability Assessment (MIDAS) - headache cease home function day count PedMIDASHeadCeasHomFuncDayCt Count the days you were not able to do things at home (i.e., chores, homework, etc.) in the last 3 months due to a headache, as part of migraine disability assessment (MIDAS) questionnaire-pediatric form. Count the days you were not able to do things at home (i.e., chores, homework, etc.) in the last 3 months due to a headache, as part of migraine disability assessment (MIDAS) questionnaire-pediatric form. Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0 92
C13933 Intima media thickness (IMT) mean far-wall measurement IMTMeanFarWallMeasr Indicates mean intima media thickness (IMT) far-wall measurement (mm) Indicates mean intima media thickness (IMT) far-wall measurement (mm) Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

millimeter
C54688 PROMIS - Global Health quality of life scale PROMISGlbHlthQualOfLfScl Scale related to an individual's rating of his/her quality of life, as part of the PROMIS Global Health Scale related to an individual's rating of his/her quality of life, as part of the PROMIS Global Health 1;2;3;4;5;1;2;3;4;5 Poor;Fair;Good;Very Good;Excellent;Poor;Fair;Good;Very Good;Excellent Alphanumeric Adult;Pediatric Supplemental 1.00 2017-04-07 15:34:25.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C55776 Imaging ictal headache since onset duration ImagIctHeadSinceOnsetDur The duration of time since the onset of the subject's headache if it was ictal. The duration of time since the onset of the subject's headache if it was ictal. Numeric Values Adult;Pediatric Supplemental 1.00 2017-05-31 12:21:21.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C13953 Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up indicator COGIFFollowupInd Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C13879 Imaging modality vessel imaging angiography type ImgModltyVesselImgAngioTyp Indicates imaging modality for vessel imaging angiography Indicates imaging modality for vessel imaging angiography DSA;MRA;CTA;CBCT Digital subtraction angiography;Magnetic resonance angiography;Computer tomography angiography;CBCT Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Multiple Pre-Defined Values Selected

C18901 Sickle cell disease vessel anatomic other text SickleCellDisVesselAntmicOTH The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C56395 Conners Continuous Performance Test 3rd Edition (CPT3) - Vigilance hit reaction time inter-stimulus interval change value ConnersCPT3VigHRTISIChngVal The change in response speed at various inter-stimulus intervals (ISIs), as part of the Conners Continuous Performance Test 3rd Edition (CPT3). The change in response speed at various inter-stimulus intervals (ISIs), as part of the Conners Continuous Performance Test 3rd Edition (CPT3). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-09 15:46:09.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C10570 Imaging contrast agent used indicator ImgContrastAgentUsedInd Indicator as to whether or not an imaging contrast agent was used for the scan as part of Diffusion Tensor Imaging (DTI). Indicator as to whether or not an imaging contrast agent was used for the scan. Yes;No;Unknown;Not applicable Yes;No;Unknown;Not applicable Alphanumeric Adult;Pediatric Supplemental 3.00 2013-08-28 16:08:00.453 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C14024 Vasospasm criterion value VasoCriterionVal Indicates vasospasm criterion value Indicates vasospasm criterion value Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C13912 Imaging plaque composition result ImgPlaqCompositionReslt Indicates plaque composition Indicates plaque composition Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X 255

Free-Form Entry

C21504 Wechsler Adult Intelligence Scale IV (WAIS IV) - Digit span sequencing subtest item score WAISIVDSSSubtestItemScore Item score, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Sequencing subtest Item score, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Sequencing subtest 0;1;2 0;1;2 Numeric Values Adult;Pediatric Supplemental 1.10 2018-07-30 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C56437 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Full Scale IQ 4 confidence interval upper bound value WASIIIFullSclIQ4ConfIntUppVal The upper bound of the subject's Full Scale IQ-4 confidence interval, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). The upper bound of the subject's Full Scale IQ-4 confidence interval, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 13:06:29.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C12494 Imaging pons abnormal indicator ImgPonsAbnrmlInd Indicator of whether the pons appears normal or abnormal in the image studies Indicator of whether the pons appears normal or abnormal in the image studies Abnormal;Normal;Abnormal;Normal Abnormal;Normal;Abnormal;Normal Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C15568 Imaging post-processing method name ImgPstprocssMethdName Method used for image post-processing Method used for image post-processing Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 PhenX CDEs Additional Proposed Instruments Phen-X 255

Free-Form Entry

C13944 Imaging color flow indicator ImgColorFlowInd Indicates color flow Indicates color flow Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C18693 Imaging contrast agent method other text ImgContrastAgentMethodOTH The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration Alphanumeric Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C00023 Hand preference type HandPrefTyp Hand which the participant/subject uses predominantly, not necessarily the hand he/she writes with exclusively. Hand which the participant/subject uses predominantly, not necessarily the hand he/she writes with exclusively. Left hand;Right hand;Both hands;Unknown;Forced right Left hand;Right hand;Both hands;Unknown;Forced right Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

2180147 DeBaun Forms
C14002 Extracranial stenosis collateral artery anatomic site ExtracranStenCollArtAntmicSite The site of parallel arteries having extracranial stenosis. The site of parallel arteries having extracranial stenosis. OA;ACA;VA Ophthalmic artery;Anterior cerebral artery;Vertebral artery Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C13891 Thrombolysis in Cerebral Infarction (TICI) perfusion scale grade TICIPerfScaleGrade Indicates Thrombolysis in Cerebral Infarction (TICI) perfusion scale grade indicator Indicates Thrombolysis in Cerebral Infarction (TICI) perfusion scale grade indicator Grade 0;Grade 1;Grade 2;Grade 2b;Grade 3 No perfusion. No antegrade flow beyond the point of occlusion;Penetration with Minimal Perfusion. The contrast material passes beyond the area of obstruction but fails to opacify the entire cerebral bed distal to the obstruction for the duration of the angiographic run;Partial Perfusion. The contrast material passes beyond the obstruction and opacifies the arterial bed distal to the obstruction. However, the rate of entry of contrast into the vessel distal to the obstruction and/or its rate of clearance from the distal bed are perceptibly slower than its entry into and/or clearance from comparable areas not perfused by the previously occluded vessel, eg, the opposite cerebral artery or the arterial bed proximal to the obstruction. Grade 2a=Only partial filling (<2/3) of the entire vascular territory is visualized;Complete filling of all of the expected vascular territory is visualized, but the filling is slower than normal;Complete Perfusion. antegrade flow into the bed distal to the obstruction occurs as promptly as into the obstruction and clearance of contrast material from the involved bed is as rapid as from an uninvolved other bed of the same vessel or the opposite cerebral artery. Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C21483 Wechsler Adult Intelligence Scale IV (WAIS IV) - Digit span forward subtest response text WAISIVDSFRespnsTxt Participant response, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Forward subtest Participant response, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Forward subtest Alphanumeric Adult;Pediatric Supplemental 1.00 2015-07-22 11:32:44.0 PhenX CDEs Additional Proposed Instruments Phen-X 50

Free-Form Entry

C56414 Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) - Verbal Comprehension T score sum value WASIIIVerbCompTScoreSumVal The sum of the T scores the subject received on the Verbal Comprehension subtests, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) The sum of the T scores the subject received on the Verbal Comprehension subtests, as part of the Wechsler Abbreviated Scale of Intelligence - Second Edition (WASI-II) Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 11:35:16.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C12469 Imaging magnetic resonance imaging session number ImgMRISessnNum Number distinguishing the Magnetic Resonance Imaging (MRI) session from other sessions Number distinguishing the Magnetic Resonance Imaging (MRI) session from other sessions Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

1 3
C14035 VMR response result VMRResponseReslt Indicates vasomotor response (VMR) response result Indicates vasomotor response (VMR) response result Abnormal;Normal;Abnormal;Normal Abnormal;Normal;Abnormal;Normal Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C13923 Imaging power doppler result ImgPowerDopplerReslt Indicates power doppler result Indicates power Doppler result Flow;No flow Flow;No flow Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C54606 Brief Test of Executive Function Second Edition (BRIEF 2) - Inhibit total raw scale score BRIEF2InhbtTtlRwSclScore Total score of the raw scale for the inhibit function, as part of the Brief Test of Executive Function Second Edition (BRIEF 2) Total score of the raw scale for the inhibit function, as part of the Brief Test of Executive Function Second Edition (BRIEF 2) Numeric Values Adult;Pediatric Supplemental 1.00 2017-03-22 09:57:02.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C12505 Imaging eye abnormality indicator ImgEyeAbnrmlyInd Indicator of whether eye abnormalities are present Indicator of whether eye abnormalities are present Yes;No;Unknown Yes;No;Unknown Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C13241 National Institutes of Health Stroke Scale (NIHSS) - Sensory score NIHSSSensoryScore Sensory abilities assessed using the NIH Stroke Scale (NIHSS) Sensory abilities assessed using the NIH Stroke Scale (NIHSS) 0;1;2;UN;0;1;2;UN Normal: no sensory loss.;Mild to moderate sensory loss: patient feels pinprick is less sharp or is dull on the affected side, or there is a loss of superficial pain with pinprick but patient is aware he/she is being touched.;Severe to total sensory loss: patient is not aware of being touched in the face, arm, and leg.;Unexaminable (intubated/paralyzed);Normal: no sensory loss.;Mild to moderate sensory loss: patient feels pinprick is less sharp or is dull on the affected side, or there is a loss of superficial pain with pinprick but patient is aware he/she is being touched.;Severe to total sensory loss: patient is not aware of being touched in the face, arm, and leg.;Unexaminable (intubated/paralyzed) Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

DeBaun Forms
C18856 Imaging ventricle abnormality other text ImgVentrclAbnrmlyOTH The free-text field related to 'Imaging ventricle abnormality type' specifying other text. The type of abnormality in the ventricles on the image The free-text field related to 'Imaging ventricle abnormality type' specifying other text. The type of abnormality in the ventricles on the image Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X 4000

Free-Form Entry

C56381 Conners Continuous Performance Test 3rd Edition (CPT3) - Inattentiveness commission count ConnersCPT3InaCommCt The number of incorrect responses to non-targets, as part of the Conners Continuous Performance Test 3rd Edition (CPT3). The number of incorrect responses to non-targets, as part of the Conners Continuous Performance Test 3rd Edition (CPT3). Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-09 15:30:42.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

0
C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90° pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

millisecond
C14013 Intracranial stenosis mean velocity criterion value IntracranStenoMnVlctyCriterVal Indicates intracranial stenosis mean velocity criterion Indicates intracranial stenosis mean velocity criterion Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Free-Form Entry

C13902 Imaging acute stroke study type ImgAcutStokStudTyp Indicates imaging acute stroke study type Indicates imaging acute stroke study type Initial;Follow-up 1;Follow-up 2 Initial;Follow-up 1;Follow-up 2 Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C21494 Wechsler Adult Intelligence Scale IV (WAIS IV) - Digit span backward subtest trial number WAISIVDSBTrialNum Trial number, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Backward subtest Trial number, as part of Wechsler Adult Intelligence Scale IV (WAIS IV) Digit Span Backward subtest 1;2 Trial 1;Trial 2 Alphanumeric Adult;Pediatric Supplemental 1.00 2015-07-22 11:32:44.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

C56426 Confidence interval level type ConfIntrvlLvlTyp The level of confidence for the confidence interval. The level of confidence for the confidence interval. 90%;95% 90%;95% Numeric Values Adult;Pediatric Supplemental 1.00 2017-06-12 12:53:52.0 PhenX CDEs Additional Proposed Instruments Phen-X

Single Pre-Defined Value Selected

Displaying 101 - 150 of 378
CSV