Sub-Domain: Assessments and Examinations
CRF: Functional Magnetic Resonance Imaging (fMRI)
CDE ID | CDE Name | Variable Name | Definition | Short Description | Additional Notes (Question Text) | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guideline) | Sub Domain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | Source | Form Set | Form | Field | Domain | CDASH Variable | CDASH Definition | CDASH Label | Controlled Terminology | Prompt | Essentiality | Question Text | CDASH imp guidance | SDTM IG target | csDSR | PhenX | Data Type | CRF Completion Inst | SDTMIG Target Var | SDTMIG Target Map | Codelist Name | PVs | Pre Pop Value | Query Display | List Style |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C55778 | Imaging inter peri ictal next headache start duration | ImagInterPeriIctNextHeStartDur | The duration of time until the start of the subject's next inter-ictal or peri-ictal headache. | The duration of time until the start of the subject's next inter-ictal or peri-ictal headache. | If inter-ictal or peri-ictal, duration of time until start of next headache | Numeric Values |
Include units |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-05-31 12:23:34.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C15598 | Imaging stimulation on period duration | ImgStimlOnPerDur | Duration on period of the stimulation | Duration on period of the stimulation | Duration on period | Numeric Values |
Record in minutes/seconds |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C15638 | Imaging multiple comparisons method text | ImgMultComparMethdTxt | Type of method(s) chosen for correcting for multiple comparisons | Text description of method(s) chosen for correcting for multiple comparisons | Describe the method chosen for correcting multiple comparisons | Alphanumeric |
Describe the method chosen correcting multiple comparisons |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C56606 | Region coordinate z value | RegCoordZVal | Value representing the region's z coordinate. | Value representing the region's z coordinate. | Region coordinates | Numeric Values |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:22:54.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C08240 | Imaging flip angle measurement | ImgFlipAngleMeasr | Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle | Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle | Flip angle (FA) | Numeric Values |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
degree | ||||||||||||||||||||||||||||||
C18716 | Imaging scanner manufacturer other text | ImgScannerManufOTH | The free-text field related to 'Imaging scanner manufacturer name' specifying other text. Name of manufacturer of imaging scanner | The free-text field related to 'Imaging scanner manufacturer name' specifying other text. Name of manufacturer of imaging scanner | Other, specify | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2014-05-27 13:34:46.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 4000 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C10842 | Imaging analysis software name | ImgAnlysisSftwrName | Name of the software used for data processing or analysis of the imaging study. | Name of the software used for data processing or analysis of the imaging study. | What processing tool(s)/package(s) type and version was used for analyzing the data? | FSL;SPM;AFNI;Brain Voyager;IMAGEJ;FreeSurfer;SLICER;MRICron;LC model;Other, specify | FSL;SPM;AFNI;Brain Voyager;IMAGEJ;FreeSurfer;SLICER;MRICron;LC model;Other, specify | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Multiple Pre-Defined Values Selected |
|||||||||||||||||||||||||||||
C55782 | Imaging scanner software hardware update text | ImagScanSoftHardUpdateTxt | Text describing any scanner software or hardware updates during the time the study was performed. | Text describing any scanner software or hardware updates during the time the study was performed. | Scanner software or hardware updates during study performance | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-05-31 12:43:09.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C15600 | Imaging stimulation off period duration | ImgStimlOffPerDur | Duration of off period of the stimulation | Duration of off period of the stimulation | Duration off period | Numeric Values |
Record in minutes/seconds |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C15639 | Imaging coordinate of significant cluster text | ImgCoordSigClustrTxt | Text representing the coordinate of significant clusters | Text representing the coordinate of significant clusters | If applicable, indicate the coordinate of significant clusters | Alphanumeric |
If applicable, specify the coordinate of significant clusters. If not applicable select 'N/A' |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C56607 | Imaging region size measurement | ImagRegSizeMeasr | The measurement of the size of the imaging region. | The measurement of the size of the imaging region. | Region size (mm) | Numeric Values |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:25:31.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
millimeter | ||||||||||||||||||||||||||||||
C08241 | Imaging field of view axis 1 measurement | ImgFieldViewAxis1Measr | Axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Field of view | Numeric Values |
Answer should be recorded as a dimension (AAxAA) in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
millimeter | ||||||||||||||||||||||||||||||
C18718 | Imaging scanner strength other text | ImgScannerStrgthOTH | The free-text field related to 'Imaging scanner strength value' specifying other text. Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | The free-text field related to 'Imaging scanner strength value' specifying other text. Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2014-05-27 13:34:46.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 4000 |
Free-Form Entry |
Tesla | |||||||||||||||||||||||||||||
C10843 | Imaging analysis software version number | ImgAnlysisSftwrVrsnNum | The version number of the software used for quantitative analysis of the imaging study | The version number of the software used for quantitative analysis of the imaging study | Version | Alphanumeric |
Answer for each processing tool/package used to analyze the data. |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-22 16:57:17.79 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 4000 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C56594 | Imaging significant cluster size text | ImagSigClustSizeTxt | Text describing the size of any significant clusters found. | Text describing the size of any significant clusters found. | If applicable, indicate the size of the significant clusters | Alphanumeric |
If not applicable, select 'N/A'. |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-16 10:55:22.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C15603 | Imaging randomization technique type | ImgRandTchTyp | The type of randomization technique used during stimulation | The type of randomization technique used during stimulation | Randomization technique | Randomized delivery;Non-randomized delivery | Randomized delivery;Non-randomized delivery | Alphanumeric |
Choose one. Report whether the order of the stimuli or order of on and off-periods was random or non-random. |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||
C15640 | Imaging corrective analysis P-values number | ImgCorrecAnlsysPValNum | P-values used for any corrective analysis | P-values used for any corrective analysis | If applicable, indicate the p-values used for any correlative analysis | Numeric Values |
If applicable, specify the coordinate of significant clusters. If not applicable select 'N/A' |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C56608 | Imaging evoked functional scan stimulation type | ImagEvoFuncScanStimTyp | The type of stimulation used for the patient's evoked functional scan, if applicable. | The type of stimulation used for the patient's evoked functional scan, if applicable. | Type of stimulation, if applicable | Sensory;Non-painful;Painful | Sensory;Specify modality: e.g. visual/auditory/olfactory/gustatory/tactile;Specify modality: e.g. thermal, visual, chemical | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:32:17.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Multiple Pre-Defined Values Selected |
|||||||||||||||||||||||||||||
C08242 | Imaging acquisition duration | ImgAcquisitionDur | Duration of the imaging scan in minutes | The duration of the imaging acquisition, in minutes | Scan time duration | Numeric Values |
Record in minutes |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-24 11:38:01.2 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
minute | ||||||||||||||||||||||||||||||
C19019 | Imaging acquisition type other text | ImgAcquisitionTypOTH | The free-text field related to 'Imaging acquisition type' specifying other text. Type of imaging acquisition | The free-text field related to 'Imaging acquisition type' specifying other text. Type of imaging acquisition | Other, specify | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 4000 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C13965 | Imaging paradigm task design type | ImgParadigmTaskDesignTyp | Nature of stimuli presented | Nature of stimuli presented | Reconstruction method used | Block Design;Event related;Block Design;Event related | Block Design;Event related;Block Design;Event related | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2012-10-05 00:00:00.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Multiple Pre-Defined Values Selected |
|||||||||||||||||||||||||||||
C56598 | Imaging functional scan patient task type | ImagFuncScanPtTaskTyp | The type of task that the patient performed for the evoked functional scan, if applicable. | The type of task that the patient performed for the evoked functional scan, if applicable. | Type of patient task, if applicable | Motor;Cognitive;Other, specify | Motor;Cognitive;Other, specify | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:05:48.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||
C15606 | Imaging multiple evoked functional acquisitions indicator | ImgMultEvokFuncAcqInd | Multiple evoked functional acquisitions | Multiple evoked functional acquisitions | Are there multiple evoked functional acquisitions? | Yes;No | Yes;No | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||
C15642 | Imaging statistical parametric mapping contrasts text | ImgStatParMapContTxt | Define contrasts in statistical parametric mapping | Define contrasts in statistical parametric mapping | Define contrasts | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C56609 | Imaging acquisition type text | ImagAcquiTypTxt | Text describing the type of acquisition used during imaging. | Text describing the type of acquisition used during imaging. | Acquisition type | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:41:20.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C08243 | Imaging matrix size value | ImgMatrixSizeVal | Value representing the imaging matrix size in millimeters | Value representing the imaging matrix size in millimeters | Matrix size | Alphanumeric |
Record in mm |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-22 09:34:41.527 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
millimeter | ||||||||||||||||||||||||||||||
C19020 | Imaging stimulation other text | ImgStimltnOTH | The free-text field related to 'Imaging stimulation type' specifying other text. Type of stimulation | The free-text field related to 'Imaging stimulation type' specifying other text. Type of stimulation | Other, specify | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 4000 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C15529 | Imaging quality assurance/quality control (QA/QC) implemented techniques text | ImgQAQCImplentTxt | Free text field to describe the quality assurance techniques implemented. | Free text field to describe the quality assurance techniques implemented. | What measures of quality assurance scans were used? | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 4000 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C56599 | Imaging functional scan patient task other text | ImagFucScanPtTaskOthrTxt | Text describing another patient task performed during the evoked functional scan, if applicable. | Text describing another patient task performed during the evoked functional scan, if applicable. | Other, specify | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:07:43.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C15609 | Imaging rest duration | ImgRestDur | The rest duration between multiple evoked functional acquisitions | The rest duration between multiple evoked functional acquisitions | If there are multiple evoked functional acquisitions, what is the rest duration in between acquisitions? | Numeric Values |
Record in seconds. Report the duration of time between each functional acquisition. |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
second | ||||||||||||||||||||||||||||||
C15643 | Imaging statistical group analysis test text | ImgStatGrpAnalTstTxt | Statistical tests used for group analysis | Statistical tests used for group analysis | What were the statistical tests used for group analysis? | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C56610 | Imaging data denoised indicator | ImagDataDenInd | The indicator relating to whether the data was denoised during preprocessing. | The indicator relating to whether the data was denoised during preprocessing. | Was the data denoised? | No;Yes | No;Yes | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 11:15:07.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||
C08244 | Imaging slice thickness value | ImgSliceThicknessVal | Value of the thickness of the slice measured in millimeters (mm) | Value of the thickness of the optical slice measured in millimeters (mm) | Slice thickness (mm) | Numeric Values |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
0 | 99 | millimeter | ||||||||||||||||||||||||||||
C19330 | Sensory evoked potential stimulation count | SEPStimulationCt | The number of stimulations in sensory evoked potential. | The number of stimulations in sensory evoked potential. | Total number of stimulations? | Numeric Values |
Report the total number of times that the patient ewas stimulated during the study. |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2014-06-09 16:27:34.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C15536 | Imaging paradigm approach type | ImgPardgmApprochTyp | The types of approach of imaging paradigm | The types of approach of imaging paradigm | Approach | Evoked Functional Scan with Stimulation;Evoked Functional Scan with Patient Task;Resting State Functional Imaging;Perfusion Imaging;Other | Evoked Functional Scan with Stimulation;Evoked Functional Scan with Patient Task;Resting State Functional Imaging;Perfusion Imaging;Other | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Multiple Pre-Defined Values Selected |
|||||||||||||||||||||||||||||
C56600 | Imaging functional scan performed task count | ImagFuncScanPerfTaskCt | The total number of performed tasks during the patient's functional scan. | The total number of performed tasks during the patient's functional scan. | Total number of performed tasks? | Numeric Values |
Report the total number of times that the patient performed a task during the study |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:09:08.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
0 | ||||||||||||||||||||||||||||||
C15611 | Imaging standard average brain text | ImgStandrdAvgBrnTxt | Text representing the standard average brain used | Text representing the standard average brain used | Report standard average brain used | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
||||||||||||||||||||||||||||||
C18011 | Imaging motion correction technique pass criteria text | ImgMotCorrTechPasCritTxt | Text of correction technique and pass criteria text | Type of correction technique and pass criteria text | Describe motion correction technique and the pass criteria text | Alphanumeric | No references available | Adult | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C56611 | Imaging high low pass filter approach used indicator | ImagHighLowPassFiltAppUsedInd | The indicator relating to whether the High/Low Pass filter approach was used during preprocessing. | The indicator relating to whether the High/Low Pass filter approach was used during preprocessing. | Was High/Low Pass filter approach used? | No;Yes | No;Yes | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 11:16:06.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||
C08245 | Imaging slice count | ImgSliceCt | Count representing the total number of single image planes captured during imaging acquisition | Count representing the total number of single image planes captured during imaging acquisition | Number of slices | Numeric Values |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C55773 | Imaging MRI scanner used count | ImagMRIScanUsedCt | The number of different MRI scanners that were used on the subject. | The number of different MRI scanners that were used on the subject. | Number of differenet MRI scanners used | Numeric Values |
Report the number of different MRI scanners that were used for imaging participants during the study |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-05-31 12:11:13.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C15580 | Imaging acquisition type | ImgAcquisitionTyp | Type of imaging acquisition | Type of imaging acquisition | Acquisition type | EPI;SSFSP;Spiral;Other,specify;EPI;SSFSP;Spiral;Other,specify | Echo Planar Imaging (EPI);Steady State Free Precession (SSFSP);Spiral;Other, specify;Echo Planar Imaging (EPI);Steady State Free Precession (SSFSP);Spiral;Other, specify | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Multiple Pre-Defined Values Selected |
|||||||||||||||||||||||||||||
C56601 | Imaging preprocessing method performed text | ImagProcMethdPerfmdTxt | Text specifying the details of any imaging preprocessing methods that were performed. | Text specifying the details of any imaging preprocessing methods that were performed. | If one of the above is selected, specify details | Alphanumeric | No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:14:53.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C02494 | Imaging study date and time | ImgStdyDateTime | Date (and time, if applicable and known) the radiologic study was obtained. | Date (and time, if applicable and known) the radiologic study was obtained. | Date of scan | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C15623 | Imaging nonstimulation fixation landmark indicator | ImgNonstimFixLandInd | Type of fixation landmark | Type of fixation landmark | Was a fixation landmark used? | Yes;No | Yes;No | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||
C18013 | Imaging spatial normalization name | ImgSpatNormName | Name of spatial normalization approach transformation from functional space to a standard brain space | Name of spatial normalization approach transformation from functional space to a standard brain space | Describe the spatial normalization approach transformation from functional space to a standard brain space | Alphanumeric | No references available | Adult | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics | 255 |
Free-Form Entry |
|||||||||||||||||||||||||||||||
C08264 | Imaging raw data reconstruction method type | ImgRawDataReconstructMthdTyp | The type of method used for reconstruction of raw data from the imaging scan | The type of method used for reconstruction of raw data from the imaging scan | Reconstruction method used | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-22 09:34:41.527 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||||
C55774 | Imaging headache relation time type | ImagHeadacheRelTimeTyp | The type of timing of the imaging in relation to headache. | The type of timing of the imaging in relation to headache. | Timing of imaging in relation to headache | Inter-Ictal;Ictal;Peri-Ictal | Inter-Ictal;Ictal;Peri-Ictal | Alphanumeric |
Report the timing of imaging in relation to the headache. The precise time windows for peri-ictal and inter-ictal vary with headache type. For episodic migraine, an interval of at least 72h from the last and before the next attack is generally accepted for "inter-ictal". |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-05-31 12:14:56.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |
|||||||||||||||||||||||||||||
C15585 | Imaging stimulation type | ImgStimlTyp | Type of stimulation | Type of stimulation | Type of stimulation | Visual;Sensorial;Other, specify: | Visual;Sensorial;Other, specify: | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Multiple Pre-Defined Values Selected |
|||||||||||||||||||||||||||||
C56602 | Imaging analysis approach type | ImagAnalysisAppTyp | The analysis approach that was made for imaging. | The analysis approach that was made for imaging. | Analysis Type | Region of interest;Whole brain;Independent Components Analysis;Other, specify | Region of interest;Whole brain;Independent Components Analysis;Other, specify | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Supplemental ? Highly Recommended | 1.00 | 2017-06-19 10:16:40.0 | Functional Magnetic Resonance Imaging (fMRI) | Assessments and Examinations | Imaging Diagnostics |
Single Pre-Defined Value Selected |